P.540
FIBER PROTECTOR TEST RESULTS |
1.TENSILE STRENGTH TEST | 2.COMPRESSION BREAKING LOAD TEST | 3.BEND-BREAKING LOAD TEST | 4.TEST CERTIFICATE |
2.COMPRESSION BREAKING LOAD TEST
METHOD OF TEST | PURPOSE OF THE TEST |
COMRESS 100mm FIBER PROTECTOR 1mm/MINUTE UNTIL IT BEGINS DEFORMED. THE RESULT ON THE TABEL IS COMPRESSION BREAKING LOAD WEIGHT. |
TO GET DATA OF COMPRESSION BREAKING LOAD WEIGHT THAT FIBER PROTECTOR BEGIN TO DEFORMED. |
RESULTS | These tests were performed by IS-10T and RS-2 made by Shimazu Co., Ltd
at Chibaken Mechanical-Metal Examination Institute and Tokyo-Metropolitan-Mechanical-Technology
Center on 08/28/1989. Observer: Shimizu, Hagitec Co., Ltd. *Remarks*@These datas are only for reference for the products. |
||
TYPE | Range/kg | Load/kg | |
KS-1.8N | 2000 | 600 | |
KS-5N | 2000 | 540 | |
KS-7N | 2000 | 340 | |
SA-4N | 2000 | 830 | |
IS-4N | 2000 | 1100 | |
SX-8N | 2000 | 1150 | |
SASP-8.5N | 2000 | 760 |