P.539
FIBER PROTECTOR TEST RESULTS |
1.TENSILE STRENGTH TEST | 2.COMPRESSION BREAKING LOAD TEST | 3.BEND-BREAKING LOAD TEST | 4.TEST CERTIFICATE |
1.TENSILE STRENGTH TEST: FIBER PROTECTOR
METHOD OF TEST | PURPOSE OF THE TEST |
COMPRESS 200mm FIBER PROTECTOR 10mm/MINUTE UNTIL IT BREAKS. THE RESULT ON THE TABLE IS WEIGHT OF BREAKING POINT. |
TO GET DATA OF TENSILE STRENGTH ON SECTION (b). |
RESULTS | |||
TYPE | Range/kg | WEIGHT OF BREAKING POINT kg | MEMO |
KS-1.5N | 500 | 23.0 | * |
KS-1.8N | 500 | 20 | * |
KS-2.2N | 500 | 23 | * |
KS-3N | 500 | 39.2 | * |
KS-4N | 500 | 69.1 | * |
KS-5N | 500 | 60 | * |
KS-6N | 500 | 73.2 | * |
KS-7N | 500 | 68.2 | * |
KS-8N | 500 | 94 | * |
KS-9N | 500 | 80.1 | * |
KS-13N | 500 | 87.3 | * |
KS-15N | 500 | 70.4 | * |
KSP-4N | 500 | 74.5 | CASING +PVC |
SA-4N | 500 | 106 | * |
SA-8N | 500 | 130 | * |
SX-5N | 500 | 130 | * |
SX-8N | 500 | 224 | * |
IS-9N | 500 | 220 | * |
SASP-8.5N-0,9 | 500 | 124 | * |
SAP-8N | 500 | 140 | SEMI-INTER+PVC |
SABP-8N | 500 | 230 | SEMI-INTER+IRON BRAIDED |
These tests were performed by IS-10T and RS-2 made by Shimazu Co., Ltd
at Chibaken Mechanical-Metal Examination Institute and Tokyo-Metropolitan-Mechanical-Technology
Center on 08/28/1989. |