P.539

Back Home
FIBER PROTECTOR TEST RESULTS
1.TENSILE STRENGTH TEST 2.COMPRESSION BREAKING LOAD TEST 3.BEND-BREAKING LOAD TEST 4.TEST CERTIFICATE

1.TENSILE STRENGTH TEST: FIBER PROTECTOR

METHOD OF TEST PURPOSE OF THE TEST
COMPRESS 200mm FIBER PROTECTOR 10mm/MINUTE UNTIL IT BREAKS.
THE RESULT ON THE TABLE IS WEIGHT OF BREAKING POINT.

TO GET DATA OF TENSILE STRENGTH ON SECTION (b).
RESULTS
TYPE Range/kg WEIGHT OF BREAKING POINT kg MEMO
KS-1.5N 500 23.0 *
KS-1.8N 500 20 *
KS-2.2N 500 23 *
KS-3N 500 39.2 *
KS-4N 500 69.1 *
KS-5N 500 60 *
KS-6N 500 73.2 *
KS-7N 500 68.2 *
KS-8N 500 94 *
KS-9N 500 80.1 *
KS-13N 500 87.3 *
KS-15N 500 70.4 *
KSP-4N 500 74.5 CASING +PVC
SA-4N 500 106 *
SA-8N 500 130 *
SX-5N 500 130 *
SX-8N 500 224 *
IS-9N 500 220 *
SASP-8.5N-0,9 500 124 *
SAP-8N 500 140 SEMI-INTER+PVC
SABP-8N 500 230 SEMI-INTER+IRON BRAIDED

These tests were performed by IS-10T and RS-2 made by Shimazu Co., Ltd at Chibaken Mechanical-Metal Examination Institute and Tokyo-Metropolitan-Mechanical-Technology Center on 08/28/1989.
Observer: Shimizu, Hagitec Co., Ltd.
*Remarks*@These datas are only for reference for the products.